Forward typing shows anti-A 3+, anti-B 3+, anti-D 3+, and th… | 마이메르시 MyMerci
이런 문제가 486개 더 있어요도전 ›
ABO/H System & Discrepancies · ABO·H 혈액형

Forward typing shows anti-A 3+, anti-B 3+, anti-D 3+, and the manufacturer's negative control 3+. Reverse typing shows A1 cells 2+ and B cells 2+ at immediate spin. The antibody screen and autocontrol react at immediate spin but are negative when prewarmed to 37 C. What is the best way to obtain a valid red cell typing?

해설
A positive negative-control tube invalidates the forward typing; here a cold IgM autoantibody coats the cells and causes spontaneous agglutination. Washing the cells several times in warm saline (or treating with DTT/2-ME) removes the autoantibody so typing can be repeated with a negative control. Enzyme treatment would only enhance the cold autoantibody.
같은 주제 다음 문제A patient's ABO testing gives the following reactions: anti-A 0, anti-B 4+, A1 reagent cel…이 문제가 수록된 문제집미국 임상병리사 MLS(ASCP/ASCPi) 문제은행·CAT98,000원
MLS(ASCP/ASCPi) 7영역 문제은행 486 문제 · 로그인 없이 바로 볼 수 있어요

마이메르시로 국가고시 완벽 대비

기출문제와 상세 해설을 무료로. 내 약점을 분석하고 진도를 관리하며 더 똑똑하게 공부하세요.

무료로 시작하기

학습 참고용입니다. 실제 임상은 최신 지침과 소속 기관 프로토콜을 따르세요.