Forward typing shows anti-A 3+, anti-B 3+, anti-D 3+, and the manufacturer's negative control 3+. Reverse typing shows A1 cells 2+ and B cells 2+ at immediate spin. The antibody screen and autocontrol react at immediate spin but are negative when prewarmed to 37 C. What is the best way to obtain a valid red cell typing?
1Report the patient as group AB, D-positive
2Repeat the reverse grouping using A2 cells
3Retype using enzyme-treated patient red cells
4Wash the red cells with warm (37 C) saline and retype with a control✓ 정답
해설
A positive negative-control tube invalidates the forward typing; here a cold IgM autoantibody coats the cells and causes spontaneous agglutination. Washing the cells several times in warm saline (or treating with DTT/2-ME) removes the autoantibody so typing can be repeated with a negative control. Enzyme treatment would only enhance the cold autoantibody.