A clean-catch urine is inoculated with a calibrated 0.001-mL loop. After overnight incubation, 120 colonies of a single gram-negative rod are counted. What colony count should be reported?
11,200 CFU/mL
212,000 CFU/mL
3120,000 CFU/mL✓ 정답
41,200,000 CFU/mL
해설
Each colony from a 0.001-mL loop represents 1,000 CFU per mL, so 120 colonies x 1,000 = 120,000 CFU/mL (1.2 x 10^5). With a 0.01-mL loop the multiplier would be 100.