# In a competitive immunoassay, patient analyte and a fixed amount of enzyme-labeled analyte compete for a limited number of antibody binding sites. As the patient analyte concentration increases, how does the bound label signal change?

> source: MyMerci (mymerci.kr)  
> url: https://mymerci.kr/pages/nclex_q.php?qn_id=729832  
> language: ko  
> subject: Immunology · 면역학

## 문제

In a competitive immunoassay, patient analyte and a fixed amount of enzyme-labeled analyte compete for a limited number of antibody binding sites. As the patient analyte concentration increases, how does the bound label signal change?

## 보기

1. It increases in direct proportion to the analyte
2. It decreases, giving an inverse relationship **✔ 정답**
3. It increases until antigen excess, then plateaus
4. It stays constant because the label amount is fixed

**정답: 2**

## 해설

In a competitive format, more patient analyte occupies more antibody sites, leaving fewer sites for the labeled analyte, so the bound signal falls as concentration rises. A signal directly proportional to concentration is characteristic of noncompetitive (sandwich) immunoassays. The fixed amount of label does not keep the bound signal constant, because the fraction bound depends on competition.

## 같은 주제 문제

- [Which immunoglobulin class is generally produced first during a primary humoral immune res…](https://mymerci.kr/pages/nclex_q.php?qn_id=471869)
- [On re-exposure to the same antigen, which change is characteristic of the secondary immune…](https://mymerci.kr/pages/nclex_q.php?qn_id=568539)
- [In an Ouchterlony double immunodiffusion plate, antiserum in the center well reacts with a…](https://mymerci.kr/pages/nclex_q.php?qn_id=729833)

---

More free questions: [기출·모의문제](https://mymerci.kr/)

_학습 참고용입니다. 실제 임상은 최신 지침과 소속 기관 프로토콜을 따르세요._