# A Westergren erythrocyte sedimentation rate is set up in the laboratory. Which technical error would most likely produce a falsely increased result?

> source: MyMerci (mymerci.kr)  
> url: https://mymerci.kr/pages/nclex_q.php?qn_id=729790  
> language: ko  
> subject: Hematology · 혈액학·지혈

## 문제

A Westergren erythrocyte sedimentation rate is set up in the laboratory. Which technical error would most likely produce a falsely increased result?

## 보기

1. The tube is left tilted a few degrees from vertical during the run **✔ 정답**
2. The test is set up 12 hours after collection on a sample kept at room temperature
3. The EDTA tube was underfilled, so the anticoagulant is in excess
4. A refrigerated sample is tested without returning it to room temperature

**정답: 1**

## 해설

Tilting the Westergren tube lets red cells slide down one side while plasma rises along the other, accelerating sedimentation and raising the ESR. Long delays at room temperature, excess EDTA, and testing cold specimens all slow sedimentation and give falsely low results.

## 같은 주제 문제

- [An automated CBC reports platelets 28 × 10^9/L with a platelet-clump flag. The patient has…](https://mymerci.kr/pages/nclex_q.php?qn_id=471846)
- [A hematology analyzer that does not automatically exclude nucleated red blood cells report…](https://mymerci.kr/pages/nclex_q.php?qn_id=471848)
- [An automated WBC count is 50.0 x 10^9/L, and the smear shows 25 nucleated red blood cells …](https://mymerci.kr/pages/nclex_q.php?qn_id=471868)
- [An asymptomatic patient has a platelet count of 28 x 10^9/L. The analyzer flags platelet c…](https://mymerci.kr/pages/nclex_q.php?qn_id=472087)
- [A patient has a red cell count of 4.0 million per microliter, a hemoglobin of 9.0 g per de…](https://mymerci.kr/pages/nclex_q.php?qn_id=568493)
- [A patient has a reticulocyte count of 6 percent and a hematocrit of 20 percent. What is th…](https://mymerci.kr/pages/nclex_q.php?qn_id=568496)
- [An automated platelet count is 40,000 per microliter, but the patient has no bleeding and …](https://mymerci.kr/pages/nclex_q.php?qn_id=568503)
- [An automated white cell count is 20.0 thousand per microliter, and the differential shows …](https://mymerci.kr/pages/nclex_q.php?qn_id=568507)

---

More free questions: [기출·모의문제](https://mymerci.kr/)

_학습 참고용입니다. 실제 임상은 최신 지침과 소속 기관 프로토콜을 따르세요._