# A telemetry unit nurse manager reviews the unit's response to alarm fatigue per The Joint Commission NPSG.06.01.01 (Reduce the harm associated with clinical alarm systems). Which staff practice represents the standard most aligned with the goal?

> source: MyMerci (mymerci.kr)  
> url: https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=en  
> language: en  
> subject: NCLEX-RN  
> category: SIPC

## Question

A telemetry unit nurse manager reviews the unit's response to alarm fatigue per The Joint Commission NPSG.06.01.01 (Reduce the harm associated with clinical alarm systems). Which staff practice represents the standard most aligned with the goal?

## Option

1. Permanently silence non-life-threatening alarms (low SpO2, low heart rate) at the central station to reduce noise.
2. Disable physiologic alarms during patient transport from the unit and re-enable them after the patient returns.
3. Customize alarm parameters and electrode care for each individual patient, escalate critical alarms to a charge nurse if not addressed in defined seconds, and review alarm settings each shift. **✔ Correct answer**
4. Allow staff to use the snooze button repeatedly so they can complete their other tasks without interruption.

**Correct answer: 3**

## Explanation

NPSG.06.01.01 addresses alarm fatigue — the desensitization that occurs when staff are exposed to large numbers of alarms, including many false or non-actionable alarms, leading to delayed or missed response to critical events. The Joint Commission expectations include: individualized alarm parameters per patient and per shift, daily electrode and lead care, defined alarm-response policies (who responds, in what timeframe, what is considered actionable), escalation pathways when an alarm is not acknowledged, and ongoing data review of alarm volumes. Choice 1 (permanently silencing alarms) is unsafe and violates the standard. Choice 2 (disabling during transport) creates a monitoring gap. Choice 4 (repeated snoozing) is the very behavior the goal is designed to prevent.

## In-depth explanation

NPSG.06.01.01 is the Joint Commission goal addressing harm from clinical alarm systems. It establishes alarms as an organizational priority and requires identification of the most important alarms to manage, written management policies, education, and ongoing review. Alarm fatigue is the sensory desensitization caused by exposure to high alarm volumes, many of which are false or non-actionable, and is a documented contributor to sentinel events including missed arrhythmias, missed apnea, and delayed escalation. Standard best practices include individualized alarm settings per patient and shift, daily electrode and lead care, written response policies with defined timeframes, escalation when alarms are not addressed, routine review of alarm volume and false-alarm rates, education on safe alarm management, and never permanently silencing or disabling alarms.

## Clinical scenario

A **telemetry unit nurse manager** reviews the unit's response to **alarm fatigue** per **NPSG.06.01.01** (Reduce the harm associated with clinical alarm systems).

## Key concepts

- **NPSG.06.01.01** — The Joint Commission goal addressing harm from clinical alarm systems. Establishes alarms as an organizational priority, requires identification of the most important alarms to manage, written policies on management, education, and ongoing review.
- **Alarm Fatigue** — Sensory desensitization to alarms caused by exposure to high alarm volumes, many of which are false or non-actionable. Documented contributor to sentinel events including missed arrhythmias, missed apnea, and delayed escalation. Targets for reduction: individualized parameters, electrode care, default alarm review.
- **Standard Best Practices** — Individualized alarm settings per patient and shift; daily electrode and lead care; written response policies with defined timeframes; escalation when alarms are not addressed; routine review of alarm volume and false-alarm rates; education on safe alarm management; never permanently silencing or disabling alarms.

## Related questions

- [A long-term care resident colonized with vancomycin-resistant enterococcus (VRE) on an adm…](https://mymerci.kr/pages/nclex_q.php?qn_id=372716&lang=en)
- [A nurse receives a phone call from the laboratory: a postoperative patient's potassium is …](https://mymerci.kr/pages/nclex_q.php?qn_id=372746&lang=en)
- [A nurse on the medical-surgical unit is reviewing reprocessing requirements for reusable e…](https://mymerci.kr/pages/nclex_q.php?qn_id=372801&lang=en)

## Read in another language

- [en](https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=en)
- [ko](https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=ko)
- [ja](https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=ja)
- [zh-TW](https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=zh-tw)
- [vi](https://mymerci.kr/pages/nclex_q.php?qn_id=372750&lang=vi)

---

More free questions: [NCLEX-RN Practice](https://mymerci.kr/pages/nclex_bank.php?lang=en)

_For study reference only. Always follow current clinical guidelines and your institution’s protocols._