학습 자료 둘러보기 →Choose your responses, then check the answer.
C. C is 1.5 inches long and 23 gauge, meeting both criteria for this client.
For a woman weighing more than 90 kg, the CDC recommends a 1.5-inch needle for adult IM vaccination; the gauge range is 22–25. Read the common ruler and the hub label together.
The observations are fictional teaching data. Apply the stated context; the selected feature does not by itself replace a complete bedside assessment.
Needle length and gauge are separate requirements; satisfying one does not satisfy both.
Needle length and gauge are separate requirements; satisfying one does not satisfy both.
A has the appropriate length but is 21 gauge, outside the recommended vaccination range. B is 23 gauge but only 1 inch long. D is 25 gauge but only 5/8 inch long.